Y-Strainers

Y-Strainers

Shop Titan Y-strainers in cast iron, ductile iron, carbon steel (A216 WCB) and aluminum bronze, with threaded, socket weld and flanged ends and 304 stainless steel screens, from 1/4" through 12". Filter by size, material, pressure class and connection. The guide below covers installation orientation, cleaning and choosing a body material.

Why install a Y-strainer

A Y-strainer catches pipe scale, weld slag and other debris before it reaches equipment that is expensive to repair: pumps, control valves, steam traps, meters, spray nozzles and heat exchangers. Install one upstream of each piece of equipment you want to protect, with isolation valves on both sides so the screen can be cleaned without draining the system.

Install it the right way

Service Horizontal line Vertical line
Liquids (water, oil, chemicals) Screen pocket pointing straight down, so debris settles in the pocket Flow downward, screen pocket pointing down
Steam and gas Screen pocket on its side (horizontal plane), so condensate cannot pool in the pocket and cause water hammer or erosion Flow downward

Always install with the cast flow arrow pointing in the direction of flow.

Cleaning and blowdown

  • Clean when the pressure drop rises. A common rule is to clean the screen when the differential pressure across the strainer reaches 5–10 psi. Gauges on each side make this easy to see.
  • Add a blowdown valve to the cap where debris loads are heavy. Opening it flushes the screen under line pressure without taking the strainer apart.
  • Keep a spare screen to shorten shutdowns, and replace the cap gasket as needed.

Choosing a body material

  • Cast iron and ductile iron: economical for water, HVAC and general utility service at lower pressures.
  • Carbon steel (WCB): higher pressure classes, steam and hydrocarbon service, and socket weld ends for welded lines.
  • Aluminum bronze: seawater and other corrosive water service.

Match the end connections to your line: socket weld, threaded, or flanged to carbon steel flanges.

Which way should a Y-strainer point?

On liquid lines, point the screen pocket down. On steam or gas lines in horizontal pipe, turn the pocket to the side so condensate does not collect.

When should I clean a Y-strainer?

When the pressure drop across it reaches about 5–10 psi, or on a regular schedule based on experience with your system.

Can a Y-strainer go in a vertical line?

Yes, with flow going downward so debris falls into the screen pocket. Upward flow would let debris fall back out.

Sort + Filter
Show